DR Power Supply
|
| |
| |
|
|
|
| |
| |
| |
|
Model |
Output |
Error |
Range |
Efficiency |
| DR-45-5 |
5V, 0-5A |
±2% |
80mV |
76.00% |
| DR-45-12 |
12V, 0-3.5A |
±1% |
120mV |
83.50% |
| DR-45-15 |
15V, 0-2.8A |
±1% |
120mV |
84.50% |
| DR-45-24 |
24V, 0-2A |
±1% |
150mV |
86.00% |
|
| |
| AC input voltage rande |
85-264VAC 120-370VDC |
| Input current |
1.5A/115V 0.75A/230V |
| AC inrush current |
Cold-start current 30A/115V 40A/230V |
| Leakage current |
<1mA/240VAC |
| DC adjustable range |
Rrted output voltage 土10% |
| Over load protection |
105-150% Hiccup mode, auto-recovery |
| Over-voltage protection |
115-135% |
| setup rise hold up time |
100ms 30ms 50ms |
| Withstand voltage |
I/P-O/P:3KvAc 1minute |
| I/P-FG:1.5KvAc 1minute |
| Working temperature |
-20℃ - +50℃, 60℃ @80%load |
| Weight/packing |
0.3Kg, 48pcs / 14.4Kg 1.06CUFT |
|
| |
| |
|
Model |
Output |
Error |
Range |
Efficiency |
| DR-120-12 |
12V, 0-10A |
±2% |
80mV |
80% |
| DR-120-24 |
24V, 0-5.0A |
±1% |
80mV |
84% |
| DR-120-48 |
48V, 0-2.5A |
±1% |
100mV |
85% |
|
| |
| AC input voltage rande |
88-132VAC 176-264VDC |
| Input current |
3.3A/115V 2A/230V |
| AC inrush current |
Cold-start current 30A/115V 60A/230V |
| Leakage current |
<3.5mA/240VAC |
| DC adjustable range |
Rrted output voltage 土10% |
| Over load protection |
105-150% Hiccup mode, auto-recovery |
| Over-voltage protection |
121-142% |
| setup rise hold up time |
500ms 70ms 30ms |
| Withstand voltage |
I/P-O/P:3KvAc 1minute |
| I/P-FG:1.5KvAc 1minute |
| Working temperature |
-10℃ - +60℃ |
| Weight/packing |
0.3Kg, 48pcs / 14.4Kg 1.06CUFT |
|
| |
| |
|
Model |
Output |
Error |
Range |
Efficiency |
| DR-75-12 |
12V, 0-6.3A |
±2% |
100mV |
76% |
| DR-75-24 |
24V, 0-3.2A |
±1% |
150mV |
80% |
| DR-75-48 |
48V, 0-1.6A |
±1% |
240mV |
81% |
|
| |
| AC input voltage rande |
85-264VAC 120-370VDC |
| Input current |
1.8A/115V 0.9A/230V |
| AC inrush current |
Cold-start current 30A/115V 60A/230V |
| Leakage current |
<3.5mA/240VAC |
| DC adjustable range |
Rrted output voltage 土10% |
| Over load protection |
105-150% Hiccup mode, auto-recovery |
| Over-voltage protection |
121-142% |
| setup rise hold up time |
1000ms 60ms 50ms |
| Withstand voltage |
I/P-O/P:3KvAc 1minute |
| I/P-FG:1.5KvAc 1minute |
| Working temperature |
-10℃ - +50℃, 20%-90%RH |
| Weight/packing |
0.6Kg, 20pcs / 12Kg 1.1CUFT |
|
| |
| |
|
Model |
Output |
Error |
Range |
Efficiency |
| DRP-120-24 |
24V,0-10A |
±1% |
80mV |
84% |
| DRP-120-48 |
48V,0-5A |
±1% |
150mV |
85% |
|
| |
| AC input voltage rande |
85-132VAC 176-264VDC |
| Input current |
3.3A/115V 2A/230V |
| AC inrush current |
Cold-start current 30A/115V 60A/230V |
| Power factor |
0.95A/100-240VAC |
| Leakage current |
<3.5mA/240VAC |
| DC adjustable range |
Rrted output voltage 土10% |
| Over load protection |
105-150% Hiccup mode, auto-recovery |
| Over-voltage protection |
121-142% |
| setup rise hold up time |
500ms 70ms 30ms |
| Withstand voltage |
I/P-O/P:3KvAc 1minute |
| I/P-FG:1.5KvAc 1minute |
| Working temperature |
-10℃ - +60℃ |
| Weight/packing |
1.2Kg, 12pcs / 14.4Kg / 1.1CUFT |
|
| |
| |
| |
| |
|