Home  >> Products >> Low Voltage >> Power Supply, Inverter & Solar---Page1 >> DR Power Supply
   

DR Power Supply

 
 
 
 
 

Model

Output Error Range Efficiency
DR-45-5 5V,  0-5A ±2% 80mV 76.00%
DR-45-12 12V, 0-3.5A ±1% 120mV 83.50%
DR-45-15 15V, 0-2.8A ±1% 120mV 84.50%
DR-45-24 24V, 0-2A ±1% 150mV 86.00%
 
AC input voltage rande 85-264VAC 120-370VDC
Input current 1.5A/115V 0.75A/230V
AC inrush current Cold-start current 30A/115V 40A/230V
Leakage current <1mA/240VAC
DC adjustable range Rrted output voltage 土10%
Over load protection 105-150% Hiccup mode, auto-recovery
Over-voltage protection 115-135%
setup rise hold up time 100ms 30ms 50ms
Withstand voltage I/P-O/P:3KvAc   1minute
I/P-FG:1.5KvAc 1minute
Working temperature -20℃ - +50℃, 60℃ @80%load
Weight/packing 0.3Kg, 48pcs / 14.4Kg 1.06CUFT
 
 

Model

Output Error Range Efficiency
DR-120-12 12V, 0-10A ±2% 80mV 80%
DR-120-24 24V, 0-5.0A ±1% 80mV 84%
DR-120-48 48V, 0-2.5A ±1% 100mV 85%
 
AC input voltage rande 88-132VAC 176-264VDC
Input current 3.3A/115V 2A/230V
AC inrush current Cold-start current 30A/115V 60A/230V
Leakage current <3.5mA/240VAC
DC adjustable range Rrted output voltage 土10%
Over load protection 105-150% Hiccup mode, auto-recovery
Over-voltage protection 121-142%
setup rise hold up time 500ms 70ms 30ms
Withstand voltage I/P-O/P:3KvAc   1minute
I/P-FG:1.5KvAc 1minute
Working temperature -10℃ - +60℃
Weight/packing 0.3Kg, 48pcs / 14.4Kg 1.06CUFT
 
 

Model

Output Error Range Efficiency
DR-75-12 12V, 0-6.3A ±2% 100mV 76%
DR-75-24 24V, 0-3.2A ±1% 150mV 80%
DR-75-48 48V, 0-1.6A ±1% 240mV 81%
 
AC input voltage rande 85-264VAC 120-370VDC
Input current 1.8A/115V 0.9A/230V
AC inrush current Cold-start current 30A/115V 60A/230V
Leakage current <3.5mA/240VAC
DC adjustable range Rrted output voltage 土10%
Over load protection 105-150% Hiccup mode, auto-recovery
Over-voltage protection 121-142%
setup rise hold up time 1000ms 60ms 50ms
Withstand voltage I/P-O/P:3KvAc   1minute
I/P-FG:1.5KvAc 1minute
Working temperature -10℃ - +50℃, 20%-90%RH
Weight/packing 0.6Kg, 20pcs / 12Kg 1.1CUFT
 
 

Model

Output Error Range Efficiency
DRP-120-24 24V,0-10A ±1% 80mV 84%
DRP-120-48 48V,0-5A ±1% 150mV 85%
 
AC input voltage rande 85-132VAC 176-264VDC
Input current 3.3A/115V 2A/230V
AC inrush current Cold-start current 30A/115V 60A/230V
Power factor 0.95A/100-240VAC
Leakage current <3.5mA/240VAC
DC adjustable range Rrted output voltage 土10%
Over load protection 105-150% Hiccup mode, auto-recovery
Over-voltage protection 121-142%
setup rise hold up time 500ms 70ms 30ms
Withstand voltage I/P-O/P:3KvAc   1minute
I/P-FG:1.5KvAc 1minute
Working temperature -10℃ - +60℃
Weight/packing 1.2Kg, 12pcs / 14.4Kg / 1.1CUFT
 
 
 
 

 

 